ADAM-6018+ Thermocouple Temperature Monitoring Features
Eight Channel Thermocouple Temperature Acquisition
The ADAM-6018+ provides eight differential thermocouple input channels, enabling multiple temperature points to be monitored through one compact Ethernet I/O module. This supports efficient control panel design and reduces the number of devices needed for multi zone temperature applications.Support For Seven Thermocouple Types
The module supports J, K, T, E, R, S, and B thermocouples. This broad sensor compatibility gives engineers the flexibility to measure a wide range of industrial process temperatures using the sensor type best suited to the application.High Temperature Measurement Capability
The ADAM-6018+ supports temperature ranges from -100 to 400°C for Type T thermocouples and up to 1,800°C for Type B thermocouples. This makes it well suited for thermal processes involving ovens, furnaces, kilns, heat treatment equipment, and other high temperature production systems.16 Bit Resolution And Reliable Accuracy
The module delivers 16 bit resolution with accuracy of up to ±0.1% of full scale range for J, K, E, R, and S thermocouple types at 25°C. This measurement performance helps provide dependable temperature data for process monitoring, quality assurance, and equipment protection.Wire Burnout Detection For Sensor Diagnostics
Built in wire burnout detection helps identify disconnected or damaged thermocouple sensors. This capability allows connected systems to recognize potential sensor failures promptly and helps prevent inaccurate readings from being treated as valid process data.Ethernet Protocol Flexibility For Industrial Systems
The ADAM-6018+ supports Modbus TCP, TCP/IP, UDP, and RESTful communication. D version models also support MQTT and SNMP, providing flexible connectivity for PLCs, SCADA systems, network management platforms, cloud connected applications, and industrial databases.Standalone Logic With Peer To Peer And GCL Support
Peer to Peer connectivity and Graphic Condition Logic allow the module to be configured for direct I/O control and logic based actions. These functions can simplify automation architectures by reducing reliance on external controllers for selected monitoring and control tasks.Industrial Isolation And Environmental Durability
The ADAM-6018+ includes 2,000 VDC isolation protection, TVS and ESD protection, and power reversal protection. It is designed for operation from -10 to 70°C, with D version models supporting operation from -40 to 70°C.
ADAM-6018+ Thermocouple Input Module Technical Specifications
| Specification | ADAM-6018+ Technical Details |
|---|---|
| Product Type | 8 channel isolated thermocouple input module |
| Input Channels | 8 differential |
| Input Type | Thermocouple |
| Supported Thermocouple Types | J, K, T, E, R, S, B |
| Type J Temperature Range | 0 to 760°C |
| Type K Temperature Range | 0 to 1,370°C |
| Type T Temperature Range | -100 to 400°C |
| Type E Temperature Range | 0 to 1,000°C |
| Type R Temperature Range | 500 to 1,750°C |
| Type S Temperature Range | 500 to 1,750°C |
| Type B Temperature Range | 500 to 1,800°C |
| Accuracy At 25°C | Type J, K, E, R, S: ±0.1% FSR maximum. Type B: ±0.15% FSR maximum. Type T: ±0.2% FSR maximum |
| Resolution | 16 bit |
| Sampling Rate | 10 samples per second total |
| Span Drift | ±25 ppm/°C |
| Zero Drift | ±6 µV/°C |
| Wire Burnout Detection | Supported |
| Ethernet Interface | 1 x RJ-45, 10/100Base-T(X) |
| Supported Protocols | Modbus TCP, TCP/IP, UDP, RESTful |
| Additional D Version Protocols | MQTT and SNMP |
| Logic Functions | Peer to Peer and Graphic Condition Logic |
| Power Input | 10 to 30 VDC |
| Power Consumption | 1 W at 24 VDC |
| Isolation Protection | 2,000 VDC |
| Protective Features | TVS and ESD protection, power reversal protection |
| Operating Temperature | -10 to 70°C |
| D Version Operating Temperature | -40 to 70°C |
| Operating Humidity | 20 to 95% RH, non condensing |
| Certifications | CE, FCC, UL |
| Connectors | RJ-45 Ethernet port and plug in screw terminal block |
ADAM-6018+ Thermocouple Module Suitable Applications
The ADAM-6018+ is suited to industrial temperature measurement systems that require dependable thermocouple acquisition, network connectivity, and integration with automation or supervisory software. Its eight input channels and wide thermocouple compatibility allow a single module to monitor multiple heating zones, production processes, or equipment assets.
Industrial oven and furnace temperature monitoring
Kiln and ceramic processing systems
Heat treatment and annealing equipment
Plastic extrusion and injection molding processes
Food and beverage thermal processing
Chemical process temperature monitoring
Boiler, burner, and combustion system supervision
Metal processing and foundry temperature measurement
Semiconductor and electronics manufacturing equipment
HVAC, energy, and thermal management systems
PLC, HMI, and SCADA temperature data acquisition
Remote Ethernet based industrial temperature monitoring