SRD-N16 Wall Mounted Multichannel Data Logger

The MultiLog SRD-N16 extends the MultiLog product line with a wall mounted solution engineered for harsh and demanding environments. Its IP65-rated enclosure ensures protection against dust and water, making it ideal for locations where panel mounting is not feasible. The SRD-N16 supports up to eight universal inputs, allowing for flexible integration of temperature (RTD and thermocouple) and analog signals (current and voltage) within a single device. The clear graphic LCD display provides real-time visualization of measured values and process trends, enabling operators to monitor critical parameters with ease.

With a large internal memory capable of storing up to 3,000,000 records, the SRD-N16 offers extensive data logging capabilities. Data can be quickly transferred via USB Host (for flash drives), USB PC (wired connection), or RS-485 (Modbus RTU) for seamless integration with automation and SCADA systems. The device features two electronic relay outputs for process control and alarm signaling. Its wall mounted design, multiple power supply options, and free configuration software make the SRD-N16 a practical and adaptable solution for a wide range of industrial and environmental data acquisition needs.

Features Of The MultiLog SRD-N16 Wall Mounted Data Logger

  1. Universal Multichannel Inputs
    Supports up to eight universal inputs for RTD, thermocouple, current, and voltage signals, enabling flexible sensor integration.

  2. IP65 Rated Wall Mounted Enclosure
    Designed for reliable operation in harsh industrial and outdoor environments where panel mounting is not possible.

  3. Large Internal Memory For Data Storage
    Stores up to 3,000,000 records, ensuring long-term data logging without frequent downloads.

  4. Multiple Data Transfer And Communication Options
    Features USB Host, USB PC, and RS-485 (Modbus RTU) interfaces for easy data export and system integration.

  5. Electronic Relay Outputs For Control And Alarms
    Includes two electronic relay outputs for process control, signaling, or alarm functions.

MultiLog SRD-N16 Technical Specifications

FeatureSpecification
Number Of InputsUp to 8 (universal: current, voltage, RTD, TC)
Input Range0/4–20 mA, 0–150 mV, 0/1–5V, 0/2–10V, Pt100/500/1000, TC (K, S, J, T, N, R, B, E)
Output Type2 electronic relay NO, 24V AC/35V DC, max. 200 mA
Power Supply16–35V AC, 19–50V DC, 85–260V AC/DC, 10–13V AC, 11–16V DC
DisplayLCD, 128 x 64 pixels, graphic, with backlight
Memory Capacity8 MB internal (up to 3,000,000 records)
Data Recording Period1 s to 60 min (selectable)
CommunicationRS-485 (Modbus RTU), USB Host, USB PC
Operating Temperature0°C to +50°C (standard), -20°C to +50°C (option)
Protection ClassIP65
Case MaterialABS, polycarbonate
MountingWall
Case Dimensions166 x 161 x 103 mm

Applications For The MultiLog SRD-N16 Wall Mounted Data Logger

The MultiLog SRD-N16 is ideal for comprehensive data acquisition and process monitoring in industrial, laboratory, and environmental settings where wall mounting and environmental protection are required. Its universal inputs, robust memory, and flexible communication make it suitable for both standalone and integrated systems.

Suitable applications include:

  • Temperature and process monitoring in manufacturing plants
  • Laboratory data acquisition and research experiments
  • Environmental monitoring and compliance reporting
  • Energy management and utility metering
  • Water and wastewater treatment process logging
  • Food and pharmaceutical process validation
  • Integration with SCADA and automation systems via Modbus RTU

Please submit your product enquiry

Thank you for visiting Diversified Tech.

Please fill in the form and send through your enquiry. If you are interested in multiple products then please add the details into the message section.

We look forward to receiving your enquiry.

Thank you