The Short Answer
A hydrostatic level sensor measures the pressure exerted by the liquid above it. That pressure rises in direct proportion to the depth of the liquid, so the sensor can calculate the level. A submersible probe hangs at the bottom of the tank or well, and a vented cable references the measurement to atmospheric pressure.
The Principle
Every liquid exerts a pressure that depends only on its height and density, not on the shape or volume of the tank. This is hydrostatic pressure:
Pressure = Density × Gravity × Height (p = ρ × g × h)
For water, every 1 ft of depth adds about 0.433 psi, and every 1 m adds about 98 mbar. A sensor that knows the density can turn pressure into level directly.
Submersible Probes
A submersible level probe is a sealed pressure sensor on the end of a cable. It is lowered into the tank, well or channel until it rests just above the bottom. The cable carries power and signal, and also contains a small vent tube that lets the back of the diaphragm see atmospheric pressure. Without the vent, changes in barometric pressure would appear as false level changes.
Externally Mounted Sensors
Where a probe cannot be lowered into the liquid, a pressure transmitter mounted on a fitting near the bottom of the tank does the same job. For pressurized or sealed tanks, a differential pressure transmitter subtracts the pressure in the head space from the pressure at the bottom.
Advantages and Limitations
Advantages
- Not affected by foam, vapor, dust or tank shape.
- Simple, robust and cost-effective.
- Works in narrow wells and boreholes.
- Accurate over a wide range of depths.
Limitations
- Needs a known, stable density.
- The probe is in contact with the liquid.
- Vent tube must stay dry.
- Heavy sediment can bury the sensor.
Typical Applications
- Groundwater, well and borehole monitoring.
- Rivers, reservoirs and open channels.
- Wastewater wet wells and lift stations.
- Fuel, oil and chemical storage tanks.
Related Products
We supply submersible probes with stainless steel or ceramic sensors and a choice of cable materials.
Frequently Asked Questions
How accurate is a hydrostatic level sensor?
Typical accuracy is ±0.1% to ±0.5% of full scale, provided the liquid density is known and stable.
Does temperature affect the reading?
Temperature changes the liquid density slightly and can affect the sensor. Quality probes are temperature compensated across their working range.
Can a submersible sensor measure fuel?
Yes, if its materials are compatible and the level is scaled for the fuel density, which is lower than water.