The Short Answer
A shielded (flush) sensor has a metal band around its coil, so its field only projects forward. It can be mounted flush in metal, but it has a shorter sensing range. An unshielded (non-flush) sensor has no shield, giving a wider field and roughly 50% more range, but it needs a metal-free zone around its face.
How Shielding Changes the Field
In a shielded sensor, the ferrite core and a metal ring direct the field straight ahead. Metal at the sides has little effect. In an unshielded sensor, the field spreads sideways as well as forward, so it reaches further but also responds to nearby metal at the sides.
Comparison
Shielded (flush)
- Can be embedded flush in metal brackets.
- Shorter sensing distance.
- Better protected from side impacts.
- Easier to mount close together.
Unshielded (non-flush)
- About 1.5 to 2 times the range of a shielded sensor of the same size.
- Needs a metal-free zone around the face.
- Wider detection area.
- Needs more spacing between sensors.
Mounting Rules
- Unshielded: keep metal at least 1 × Sn away to the sides, or follow the free zone in the datasheet.
- Unshielded: leave at least 3 × Sn of clear space in front of the face to any background metal.
- Side-by-side sensors: space shielded sensors about 2 × the diameter apart, and unshielded sensors further, to stop them interfering.
- Where sensors must sit close together, use alternate-frequency versions.
Which Should You Choose?
Choose shielded sensors for most machine-building applications, especially where the sensor must be recessed in a metal fixture for protection. Choose unshielded sensors where you need maximum range, such as detecting targets with variable position, and where there is space for a metal-free zone.
Related Products
Our proximity sensor range includes both flush and non-flush designs in standard and harsh-duty housings.
Frequently Asked Questions
Is flush the same as shielded?
Yes. Flush, shielded and embeddable all describe sensors that can be mounted level with surrounding metal.
Why is my unshielded sensor always on?
Nearby metal, often the mounting bracket, is inside its field. Increase the clearance or switch to a shielded sensor.
Can I mount a shielded sensor recessed below the surface?
Yes, but leave enough clearance around the face as specified, or the sensing distance will be reduced.