RTD vs Thermocouple vs Thermistor: Which Temperature Sensor Should You Use?

The Short Answer

Use an RTD when you need accuracy and long-term stability up to about 600 °C (1,100 °F). Use a thermocouple for high temperatures, fast response or low cost, up to about 1,700 °C (3,100 °F). Use a thermistor for very precise measurement over a narrow, low temperature range, such as in electronics and HVAC.

RTD (Resistance Temperature Detector)

An RTD is a platinum element whose resistance rises predictably with temperature. The most common type, the Pt100, measures 100 Ω at 0 °C. RTDs are accurate, repeatable and stable for years, which makes them the standard choice for process measurement.

Thermocouple

A thermocouple is two dissimilar metal wires joined at the tip. A temperature difference between the tip and the other end generates a small voltage. Thermocouples are inexpensive, rugged, respond quickly and reach very high temperatures, but they are less accurate and drift more than RTDs.

Thermistor

A thermistor is a ceramic semiconductor whose resistance changes sharply with temperature, usually decreasing as temperature rises (NTC). That sensitivity gives excellent resolution, but only over a limited range, typically -50 to 150 °C, and the response is highly non-linear.

Side-by-Side Comparison

RTD

Thermocouple

Thermistor

How to Choose

Related Products

We supply temperature transmitters and the instruments that read RTD and thermocouple inputs directly.

Convert RTD and thermocouple signals to 4-20 mA. View range

Temperature control with RTD and thermocouple inputs. View range

Multichannel temperature logging. View range

Frequently Asked Questions

An RTD. A Class A Pt100 is accurate to ±0.15 °C at 0 °C, while a standard thermocouple is typically ±1 to 2 °C.

A small exposed-junction thermocouple usually responds fastest, because its tip has very little mass.

Only if the temperature is within the RTD range and the instrument input is changed to suit, since the two produce completely different signals.

More in This Category

What Is a Pt100 RTD, and What Do Class A and Class B Mean?

A Pt100 is a platinum resistance temperature detector with a resistance of exactly 100 Ω at 0 °C, rising by about 0.385 Ω per °C. Its tolerance class, defined in IEC 60751, tells you how accurate it is. Class A is ±0.15 °C at 0 °C, and Class B is ±0.3 °C at 0 °C, with the tolerance widening as temperature moves away from zero.

2-Wire vs 3-Wire vs 4-Wire RTD Connections

The number of wires decides how well the instrument can cancel the resistance of the leads. A 2-wire RTD adds the full lead resistance to the reading, causing errors on anything but very short runs. A 3-wire RTD compensates for lead resistance and is the industrial standard. A 4-wire RTD removes lead effects completely and is used for laboratory and calibration-grade accuracy.

Thermocouple Types (J, K, T, E, N) and Cold Junction Compensation Explained

Each thermocouple type uses a different pair of metals, which sets its temperature range and best uses. Type K is the general-purpose choice up to about 1,260 °C. Type J suits lower temperatures and reducing atmospheres, Type T is best for low and cryogenic temperatures, and Types R and S cover very high temperatures. Every thermocouple measures relative to its cold junction, so the instrument must apply cold junction compensation.

Need help choosing the right product?

Our engineers can help you select, configure and integrate the right sensor, instrument or industrial computer for your application.