The Short Answer
Stud mounting to a flat, spot-faced surface gives the best high-frequency response and is the choice for permanent installations. Adhesive mounting to a mounting pad is a good alternative where you cannot drill. Magnet mounting is quick and suits portable data collection, but it limits the usable frequency range.
Why Mounting Matters
The sensor can only measure what reaches it. Every mounting method acts like a spring between the machine and the sensor, with its own resonant frequency. A stiffer, lighter mounting pushes this resonance higher and keeps more of the sensor’s frequency range usable, which matters for detecting bearing and gear faults at high frequencies.
Mounting Methods Compared
10+ kHz
Stud mount
usable range
5-8 kHz
Adhesive pad
usable range
2-5 kHz
Flat magnet
usable range
Under 1 kHz
Handheld probe
usable range
Figures are typical and depend on the sensor, surface and mounting hardware.
Stud Mounting
- Drill and tap the machine to the sensor thread, usually 1/4-28 UNF or M6/M8.
- Spot-face the surface flat and perpendicular to the hole.
- Apply a thin layer of grease or coupling fluid to improve high-frequency transmission.
- Tighten to the manufacturer’s torque value.
Adhesive and Magnet Mounting
Adhesive pads are bonded to the machine with epoxy or cyanoacrylate, and the sensor screws onto the pad. They avoid drilling and give good results if the surface is clean and the adhesive layer thin.
Magnets let you move one sensor between machines. Use a flat magnet on a flat, clean ferrous surface, or a curved-surface magnet on motor housings, and always place it in the same marked spot so readings are comparable.
Where to Place the Sensor
- As close to the bearing as possible, in the load zone.
- On solid structure, not on thin covers, fins or guards.
- In the horizontal, vertical and axial directions where diagnostics need all three.
- In the same location every time for trending.
Related Products
We supply accelerometers with a choice of mounting threads, plus mounting accessories.
Frequently Asked Questions
Can I mount an accelerometer on a painted surface?
For best results, remove paint at the mounting spot. Thick paint acts as a damper and reduces high-frequency response.
Do I need to isolate the accelerometer electrically?
If you see ground loop noise, use an isolated mounting stud or a sensor with an isolated case.
Which direction should the sensor face?
Mount it in the direction of the vibration you want to measure. Radial, either horizontal or vertical, is the most common.