HLC 360H Hydrostatic Level Probe Features
Detachable Sensor And Cable Assembly
The detachable probe design allows the transmitter head to be separated from the cable assembly through a connector. This supports easier replacement, servicing and stock management.Capacitive Ceramic Measuring Element
A ceramic diaphragm provides reliable hydrostatic pressure measurement for liquid level applications, including wastewater, waste media and liquids with higher viscosity.HART Communication Capability
HART communication supports adjustment of electronic damping, offset and measuring span when the appropriate interface, cable and software are used.Wide Level Measurement Capability
Standard nominal ranges extend from 0 to 0.6 mH₂O through to 0 to 100 mH₂O. Customer specific ranges can be configured within the stated turndown capability.Strong Long Term Measurement Stability
The probe provides long term stability of up to ±(0.1 × turndown)% of span per year under reference conditions.High Temperature And Environmental Resistance
The HLC 360H is suitable for medium, electronics, ambient and storage temperatures from minus 20°C to 85°C, subject to the selected cable temperature rating.Robust Construction For Submerged Installation
The stainless steel 316L housing, IP68 ingress protection and removable POM C protection cap support reliable use in submerged and exposed environments.Hazardous Area Option
An intrinsically safe Ex ia version is available for use in specified gas and dust hazardous zones, subject to the applicable installation requirements and temperature limits.
HLC 360H Submersible Level Measurement Applications
The HLC 360H is suited to continuous liquid level measurement in demanding installations where the sensor may be exposed to wastewater, contaminated liquids, higher viscosity media or outdoor environmental conditions. Its ceramic sensing element, detachable assembly and HART configuration capability make it suitable for both new installations and maintenance focused replacement projects.
Suitable applications include:
Groundwater level measurement
Rain spillway basins
Wastewater treatment plants
Water recycling systems
Sewage handling processes
Open tanks with low filling heights
Fuel storage facilities
Tank farms
Biogas plants
Industrial water storage tanks
Process vessels containing compatible viscous liquids
HLC 360H Level Transmitter Technical Specifications
| Specification | Details |
|---|---|
| Product Model | HLC 360H |
| Brand | SENSVISION |
| Product Type | Detachable stainless steel hydrostatic level probe |
| Measuring Principle | Capacitive ceramic sensor |
| Nominal Level Ranges | 0 to 0.6, 1.6, 4, 10, 20, 50 and 100 mH₂O |
| Nominal Pressure Ranges | 0.06, 0.16, 0.4, 1, 2, 5 and 10 bar |
| Output Signal | 4 to 20 mA, two wire, with HART communication |
| Standard Supply Voltage | 12 to 36 VDC |
| Intrinsically Safe Supply Voltage | 12 to 28 VDC |
| Rated Supply Voltage | 24 VDC |
| Accuracy For PN ≥ 0.6 Bar | ±0.1% of span at turndown up to 5:1 |
| Accuracy For PN ≥ 160 mbar | ±0.2% of span at turndown up to 5:1 |
| Maximum Turndown | Up to 10:1, depending on nominal pressure range |
| Adjustable Damping | 0 to 100 seconds |
| Adjustable Offset | 0 to 80% of span |
| Mean Response Time | 140 ms without electronic damping |
| Maximum Response Time | 380 ms |
| Measuring Rate | 7 measurements per second |
| Long Term Stability | ≤ ±(0.1 × turndown)% of span per year |
| Compensated Temperature Range | Minus 20°C to 80°C |
| Permissible Temperature Range | Minus 20°C to 85°C, subject to cable selection |
| Housing Material | Stainless steel 1.4404, equivalent to 316L |
| Standard Diaphragm Material | Ceramic Al₂O₃, 96% |
| Optional Diaphragm Material | Ceramic Al₂O₃, 99.9% |
| Seal Materials | FKM or EPDM |
| Protection Cap Material | POM C |
| Cable Options | PVC, PUR, FEP and TPE U |
| Ingress Protection | IP68 |
| Weight | Approximately 650 g without cable |
| Housing Diameter | 39.5 mm |
| Electrical Protection | Permanent short circuit protection and integrated lightning protection |
| Electromagnetic Compatibility | In accordance with EN 61326 |
| Optional Explosion Protection | Ex ia for gas and dust applications |