HLC 400 Ceramic Level Probe Features
Marine Certified Level Measurement
The HLC 400 is designed for shipbuilding and offshore applications and is supported by Lloyd’s Register, DNV, ABS and CCS certification options.Capacitive Ceramic Sensing Element
The ceramic sensor provides robust hydrostatic pressure measurement with high resistance to overload and excellent compatibility with a wide range of liquid media.Wide Range Of Hydrostatic Level Measurements
Standard measuring ranges extend from 0 to 0.4 mH₂O up to 0 to 200 mH₂O, allowing the probe to be selected for shallow tanks, deep tanks and storage vessels.Reliable Accuracy And Long Term Stability
Standard accuracy is up to ±0.25% of span, with an optional accuracy of up to ±0.1% of span for nominal pressures from 0.6 bar. Long term stability is specified at up to ±0.1% of span per year.Seawater Resistant Material Option
The standard housing is stainless steel 316L, while the CuNi10Fe1Mn option provides enhanced resistance to seawater for demanding marine installations.High Temperature Measurement Capability
The HLC 400 supports permissible medium, electronics and ambient temperatures from Minus 25°C to 125°C, subject to the selected cable sheath and seal materials.Reliable Submerged Installation Protection
IP68 protection, a shielded cable with an integrated atmospheric reference tube and a removable POM C protection cap support dependable operation in submerged environments.Flexible Safety And Installation Options
Optional Ex ia intrinsic safety protection is available for gas hazardous areas. Screw in, flange and stainless steel pipe mounting arrangements provide installation flexibility.
HLC 400 Hydrostatic Level Measurement Applications
The HLC 400 is suited to continuous level measurement in marine and offshore environments where tank contents, saltwater exposure, changing operating conditions and safety requirements demand a robust submerged level probe. Its ceramic sensing technology and selectable material options also make it suitable for industrial water and compatible liquid storage applications.
Suitable applications include:
Ballast tank level monitoring
Ship draught and position monitoring
Marine service tanks
Offshore storage tanks
Seawater handling systems
Desalination plants
Drinking water abstraction systems
Freshwater storage tanks
Industrial water tanks
Process liquid storage vessels
Open tank level measurement
Hazardous area liquid level installations
HLC 400 Marine Level Transmitter Technical Specifications
| Specification | Details |
|---|---|
| Product Model | HLC 400 |
| Brand | SENSVISION |
| Product Type | Marine and offshore hydrostatic level probe |
| Measuring Principle | Capacitive ceramic pressure sensor |
| Nominal Level Ranges | 0 to 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160 and 200 mH₂O |
| Nominal Pressure Ranges | 0.04 to 20 bar |
| Pressure Reference Options | Gauge, sealed gauge and absolute |
| Sealed Gauge And Absolute Ranges | Available from 1 bar |
| Overpressure Resistance | 2 to 45 bar, depending on selected pressure range |
| Maximum Ambient Housing Pressure | 40 bar |
| Standard Output Signal | 4 to 20 mA, two wire |
| Standard Supply Voltage | 9 to 32 VDC |
| Intrinsic Safety Supply Voltage | 14 to 28 VDC |
| Rated Supply Voltage | 24 VDC |
| Standard Accuracy | Up to ±0.25% of span |
| Optional Accuracy | Up to ±0.1% of span for nominal pressure from 0.6 bar |
| Long Term Stability | Up to ±0.1% of span per year |
| Turn On Time | 700 ms |
| Mean Response Time | Less than 200 ms |
| Maximum Response Time | 380 ms |
| Measuring Rate | 5 measurements per second |
| Thermal Error | Up to ±0.1% of span per 10 K |
| Compensated Temperature Range | Minus 20°C to 80°C |
| Permissible Medium, Electronics And Ambient Temperature | Minus 25°C to 125°C, subject to cable sheath and seal selection |
| Storage Temperature | Minus 40°C to 125°C |
| Housing Material | Stainless steel 1.4404, equivalent to 316L, or optional CuNi10Fe1Mn |
| Standard Diaphragm Material | Ceramic Al₂O₃ 96% |
| Optional Diaphragm Material | Ceramic Al₂O₃ 99.9% |
| Standard Seal Material | FKM |
| Optional Seal Materials | EPDM or FFKM |
| Protection Cap Material | POM C |
| Cable Sheath | TPE U, blue, 7.4 mm diameter |
| Ingress Protection | IP68 |
| Current Consumption | Maximum 21 mA |
| Weight | Minimum 650 g without cable |
| Housing Diameter | 39.5 mm |
| Electrical Protection | Permanent short circuit protection and reverse polarity protection |
| Electromagnetic Compatibility | In accordance with EN 61326 and DNV requirements |
| Optional Temperature Element | Pt100, three wire, for 4 to 20 mA versions with cable length up to 5 m |
| Optional Explosion Protection | Ex ia for gas hazardous areas |
| Marine Approval Options | Lloyd’s Register, DNV, ABS and CCS |