HLC 900 Plastic Submersible Level Probe Features
Detachable Probe And Cable Assembly
The transmitter head connects to the cable assembly using an M12x1 four pin connector. This allows the transmitter head to be changed more easily for maintenance and stock management purposes.Semi Flush Ceramic Diaphragm For Viscous Media
The semi flush ceramic diaphragm is suitable for wastewater, sludge and other higher viscosity media where deposits can affect conventional pressure connections.Materials For Compatible Aggressive Liquids
The PP HT housing, ceramic diaphragm and FKM or EPDM seal options allow the HLC 900 to be specified for many compatible acids, alkalis and aggressive process liquids.Wide Hydrostatic Level Range Selection
Standard level ranges extend from 0 to 0.4 mH₂O up to 0 to 100 mH₂O, supporting shallow tanks, wells, treatment equipment and deeper liquid storage applications.Reliable Current Or Voltage Signal Options
The standard 4 to 20 mA two wire output operates from 9 to 32 VDC. An optional 0 to 10 V three wire output is available with a 12.5 to 32 VDC supply.Stable Accuracy For Continuous Level Monitoring
Standard accuracy is up to ±0.35% of span, with an optional accuracy of up to ±0.25% of span. Long term stability is up to ±0.1% of span per year.Submerged Construction With IP68 Protection
IP68 ingress protection, a shielded cable with integrated atmospheric pressure reference tube and integrated lightning protection on the two wire version support dependable submerged operation.Flexible Cable And Installation Options
PVC, PUR and FEP cable variants are available, together with optional cable protection through a PP HT pipe and accessories including assembly flanges and terminal clamps.
HLC 900 Applications For Wastewater And Aggressive Liquid Level Measurement
The HLC 900 is suitable for continuous hydrostatic level measurement where wastewater, sludge and compatible aggressive liquids demand a durable plastic probe with a semi flush ceramic diaphragm. Its detachable construction and flexible material options make it well suited to installations where maintenance access and media compatibility are important.
Suitable applications include:
Sewage treatment systems
Wastewater treatment plants
Water recycling facilities
Sludge tanks and sludge handling processes
Leachate collection and dumpsite monitoring
Industrial effluent tanks
Open process tanks
Acid storage vessels using compatible materials
Alkali storage vessels using compatible materials
Chemical process tanks
Contaminated water storage tanks
Industrial liquid level monitoring systems
HLC 900 Detachable Level Probe Technical Specifications
| Specification | Details |
|---|---|
| Product Model | HLC 900 |
| Brand | SENSVISION |
| Product Type | Detachable plastic submersible level probe for aggressive media |
| Measuring Principle | Hydrostatic pressure measurement with ceramic sensor |
| Nominal Level Ranges | 0 to 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60 and 100 mH₂O |
| Nominal Pressure Ranges | 0.04 to 10 bar gauge |
| Overpressure Resistance | 2 to 35 bar, depending on selected nominal pressure |
| Maximum Ambient Housing Pressure | 10 bar |
| Standard Output Signal | 4 to 20 mA, two wire |
| Standard Supply Voltage | 9 to 32 VDC |
| Optional Output Signal | 0 to 10 V, three wire |
| Optional Supply Voltage | 12.5 to 32 VDC |
| Standard Accuracy | Up to ±0.35% of span |
| Optional Accuracy | Up to ±0.25% of span |
| Long Term Stability | Up to ±0.1% of span per year |
| Mean Response Time | Less than 200 ms |
| Maximum Response Time | 380 ms |
| Measuring Rate | 5 measurements per second |
| Turn On Time | 700 ms |
| Thermal Error | Up to ±0.1% of span per 10 K |
| Compensated Temperature Range | 0°C to 50°C |
| Permissible Medium, Electronics, Ambient And Storage Temperature | Minus 20°C to 80°C, subject to selected cable temperature range |
| Housing Material | PP HT |
| Seal Materials | FKM, EPDM or other materials on request |
| Standard Diaphragm Material | Ceramic Al₂O₃, 96% |
| Optional Diaphragm Material | Ceramic Al₂O₃, 99.9% |
| Cable Sheath Options | PVC, PUR, FEP or other materials on request |
| Cable Diameter | 7.4 mm |
| Housing Diameter | 45 mm |
| Electrical Connection | M12x1 four pin connector in detachable version |
| Ingress Protection | IP68 |
| Current Consumption | Maximum 25 mA |
| Weight | Approximately 400 g without cable |
| Electrical Protection | Permanent short circuit protection and reverse polarity protection |
| Lightning Protection | Integrated on the two wire version |
| Electromagnetic Compatibility | In accordance with EN 61326 |
| Cable Protection Option | Prepared for PP HT pipe mounting, with standard pipe length up to 2 m possible |