HLS 880 Submersible Level Probe Features
Detachable Probe Head For Straightforward Maintenance
The probe head is connected to the cable assembly by a connector and can be replaced easily, helping to support efficient maintenance and stock keeping.Wide Hydrostatic Level Measurement Range
Available level ranges from 0 to 1 mH₂O to 0 to 100 mH₂O support measurement across shallow and deeper liquid installations.Choice Of Analogue Output Signals
Choose a 4 to 20 mA two wire output, or a 0 to 20 mA or 0 to 10 V three wire output, to suit the installed control or monitoring system.Durable Materials For Wetted Service
The probe combines a PP HT housing, stainless steel 1.4435 diaphragm, POM C protection cap and a choice of FKM or EPDM seals.Low Thermal Effect And Stable Performance
The design provides a thermal tolerance band of up to ±0.75% of span for nominal pressures of 0.4 bar and above, with long term stability of up to ±0.1% of span per year.Fully Submersible IP68 Protection
IP68 ingress protection supports reliable operation in immersed measurement applications.Cable And Seal Options For Application Suitability
PVC, PUR and FEP cable options are available, together with FKM or EPDM sealing materials to help match the product to the medium and operating conditions.Optional Safety And Mounting Solutions
An SIL 2 version for the 4 to 20 mA two wire output is available, along with mounting flanges, terminal clamps and an optional cable protection arrangement.
HLS 880 Applications For Immersed Liquid Level Monitoring
The HLS 880 is designed for hydrostatic level measurement in liquid storage, water management and process applications where a durable submersible probe and serviceable detachable head are beneficial. Its material options and analogue output choices make it suitable for monitoring a broad range of compatible water, sewage, fuel and oil duties.
Suitable applications include:
Groundwater level measurement
Stormwater systems
Drinking water systems
Water treatment plants
Filtered sewage monitoring
Process water recycling
Fuel storage tanks
Tank farms
Biogas plants
Oil level measurement
HLS 880 Detachable Level Transmitter Technical Specifications
| Specification | Details |
|---|---|
| Product Model | HLS 880 |
| Brand | SENSVISION |
| Product Type | Detachable plastic submersible level probe with stainless steel sensor |
| Measuring Principle | Piezoresistive hydrostatic pressure measurement |
| Nominal Level Ranges | 0 to 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60 and 100 mH₂O |
| Nominal Pressure Ranges | 0.1 to 10 bar gauge |
| Maximum Ambient Pressure At Housing | 20 bar |
| Standard Output | 4 to 20 mA, two wire |
| Optional Outputs | 0 to 20 mA, three wire, or 0 to 10 V, three wire |
| Supply Voltage For 4 To 20 mA | 8 to 32 VDC |
| Supply Voltage For SIL 2 Version | 14 to 28 VDC |
| Supply Voltage For Three Wire Outputs | 14 to 30 VDC |
| Accuracy For Nominal Pressure Below 0.4 Bar | Up to ±0.5% of span |
| Standard Accuracy For Nominal Pressure Of 0.4 Bar And Above | Up to ±0.35% of span |
| Optional Accuracy For Nominal Pressure Of 0.4 Bar And Above | Up to ±0.25% of span |
| Long Term Stability | Up to ±0.1% of span per year |
| Response Time | Less than 10 ms |
| Thermal Tolerance Band Below 0.4 Bar | Up to ±1% of span |
| Thermal Tolerance Band At 0.4 Bar And Above | Up to ±0.75% of span |
| Compensated Temperature Range | 0°C to 50°C |
| Permissible Medium, Electronics, Ambient And Storage Temperature | Minus 20°C to 80°C, subject to cable temperature range |
| Housing Material | PP HT |
| Diaphragm Material | Stainless steel 1.4435, equivalent to 316L |
| Seal Materials | FKM or EPDM |
| Protection Cap Material | POM C |
| Cable Sheath Options | PVC, PUR or FEP |
| Cable Diameter | 7.4 mm |
| Electrical Connection | Shielded cable with integrated air tube for atmospheric pressure reference |
| Current Output Load | Two wire: Rmax equals supply voltage minus minimum supply voltage divided by 0.02 A. Three wire: Rmax 500 ohms |
| Voltage Output Load | Three wire: Rmin 10 kΩ |
| Short Circuit Protection | Permanent |
| Reverse Polarity Protection | No damage, but no function |
| Lightning Protection | Integrated for two wire version |
| Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
| Current Consumption | Maximum 25 mA for current output, maximum 7 mA for voltage output |
| Weight | Approximately 400 g without cable |
| Ingress Protection | IP68 |
| Optional Functional Safety | SIL 2 according to IEC 61508 and IEC 61511, for 4 to 20 mA two wire version |