Features Of The SENSVISION PTC 350F Hygienic Low Pressure Transmitter
Capacitive Ceramic Sensor Technology For High Media Resistance
The ceramic Al₂O₃ diaphragm provides strong resistance against aggressive chemicals and process fluids while maintaining stable and repeatable measurement performance.Low Pressure Measurement From 40 Mbar Up To 20 Bar
The SENSVISION PTC 350F covers a wide span of small system pressures and filling height measurement tasks, supporting both gauge and selected absolute pressure configurations.Hygienic Process Connections For Food And Chemical Industry Compliance
Multiple hygienic mechanical connection options are available including G 1 1/2″ DIN flush, clamp according to DIN 32676, dairy pipe according to DIN 11851, Varivent®, and flange according to DIN 2501.Enhanced Accuracy Options For Precise Process Control
Standard accuracy is ≤ ± 0.35% span with an optional ≤ ± 0.25% span version to meet higher performance requirements in controlled production processes.Intrinsically Safe Ex ia Versions For Hazardous Areas
The 4.20 mA 2-wire version is available with Ex ia approval for gases and dusts with temperature class T4 and optional T6, supporting installation in explosive atmospheres.Flexible Electrical Outputs For Integration Into Automation Systems
Standard 2-wire 4.20 mA output supports robust industrial transmission, while optional 3-wire 0.10 V output enables compatibility with voltage based input systems.
Suitable Applications Of The SENSVISION PTC 350F Hygienic Process Pressure Transmitter
The SENSVISION PTC 350F is ideally suited for hygienic and chemically demanding process environments where low pressure measurement, cleanability, and resistance to aggressive or viscous media are essential. Its wide selection of sanitary process connections and ceramic sensing technology make it a reliable solution for regulated and contamination sensitive industries.
- Food industry pressure measurement in processing lines and vessels
- Chemical and petrochemical industry low pressure monitoring
- Paint and varnish production processes
- Measurement of viscous and pasty media in hygienic systems
- Filling height monitoring in tanks with sanitary fittings
- Hazardous area installations using intrinsically safe Ex ia versions
- Applications requiring enhanced chemical resistance and overpressure capability
Technical Specifications Of The SENSVISION PTC 350F Process Industry Pressure Transmitter
| Specification | Detail |
|---|---|
| Product Type | Hygienic process pressure transmitter with ceramic sensor |
| Nominal Pressure Range | 0.04 bar to 20 bar |
| Pressure Type | Gauge standard, selected absolute ranges on request |
| Accuracy | Standard ≤ ± 0.35% span, option ≤ ± 0.25% span |
| Overpressure Capability | Up to 45 bar depending on nominal range |
| Permissible Vacuum | Down to -1 bar depending on range |
| Output Signals | 2-wire 4.20 mA standard, 3-wire 0.10 V option |
| Supply Voltage 2-Wire | 9 to 32 VDC |
| Supply Voltage 2-Wire IS | 14 to 28 VDC |
| Supply Voltage 3-Wire | 12.5 to 32 VDC |
| Long Term Stability | ≤ ± 0.1% span per year |
| Turn On Time | 700 msec |
| Mean Measuring Rate | 5 per sec |
| Response Time | Mean ≤ 200 msec, max 380 msec |
| Thermal Error | ≤ ± 0.1% span per 10 K in compensated range -20 to 80 °C |
| Medium Temperature | -40 to 125 °C |
| Electronics Temperature | -40 to 85 °C |
| Storage Temperature | -40 to 100 °C |
| Diaphragm Material | Ceramic Al₂O₃ 96% standard, 99.9% option |
| Pressure Port Material | Stainless steel 1.4404 |
| Housing Material | Stainless steel 1.4404, optional field housing stainless steel 1.4435 |
| Seal Materials | FKM, EPDM, others on request |
| Short Circuit Protection | Permanent |
| Reverse Polarity Protection | No damage, but also no function |
| Vibration Resistance | 10 g RMS according to DIN EN 60068-2-6 |
| Shock Resistance | 100 g / 1 msec according to DIN EN 60068-2-27 |
| Operational Life | Greater than 100 x 10⁶ loading cycles |
| Intrinsic Safety Approval | IBExU05ATEX1069 X, Ex ia for gases and dusts |
| CE Conformity | EMC Directive 2014/30/EU |
| ATEX Directive | 2014/34/EU |