Features Of The SENSVISION PTS 310D Digital Precision Pressure Transmitter
High Accuracy Precision Pressure Measurement Performance
Provides ≤ ± 0.1% span accuracy, supporting test stands, measurement rigs, and critical monitoring where tight tolerance is required.Intelligent Digital Electronics With Active Compensation And Linearization
16 bit signal processing enables active temperature compensation and linearization for stable output across varying conditions.Configurable Offset Span And Damping For Application Matching
Parameters including electronic damping from 0 to 100 seconds, offset adjustment, and span turn down up to 10:1 can be configured with the interface and software.Wide Pressure Coverage With Turn Down Capability
Supports measurement ranges from low pressure through high pressure versions, with software adjustment within turn down limits for customised ranges.Robust Stainless Steel Construction For Industrial Media Compatibility
Stainless steel pressure port and housing with stainless steel diaphragm support long operational life and industrial durability.Hazardous Area Options For Regulated Installations
Ex ia versions are available for gases and dusts, including versions suitable for zone 0 and dust zone applications depending on approval configuration.
Applications For The SENSVISION PTS 310D Precision Pressure Transmitter
The SENSVISION PTS 310D is suited for applications that require high measurement accuracy, stable temperature performance, and the ability to digitally configure pressure ranges and damping to match real process behaviour. It is particularly useful where calibration quality and repeatability are central to system performance.
- Laboratory techniques and calibration systems
- Energy production monitoring including gas consumption and thermal energy measurement
- Industrial test benches and pressure calibration rigs
- High accuracy process monitoring in manufacturing
- Chemical and petrochemical measurement points with compatible media
- Environmental engineering systems including water, sewage, and recycling
- Screw in measurement points requiring stable long term performance
- Hazardous area installations using intrinsically safe versions
Technical Specifications Of The SENSVISION PTS 310D Precision Digital Pressure Transmitter
| Specification | Detail |
|---|---|
| Product Type | Precision pressure transmitter with intelligent digital electronics |
| Nominal Pressure Range | 0.4 bar to 600 bar depending on version |
| Vacuum Ranges | Available, including ranges such as -1 to 10 bar depending on configuration |
| Accuracy | ≤ ± 0.1% span according to EN IEC 62828-2 |
| Turn Down | Up to 10:1 with software adjustment |
| Output Signal Standard | 4.20 mA 2-wire |
| Output Signal Option | 0 to 10 V 3-wire for selected versions |
| Supply Voltage 4.20 mA | 12 to 36 VDC |
| Supply Voltage Ex ia Option | 14 to 28 VDC |
| Response Time | 5 ms for 4.20 mA, 25 ms for 0 to 10 V |
| Long Term Stability | ≤ ± (0.1 × turn down) % span per year |
| Thermal Error | 0.2% span in compensated range -20 to 80 °C, TC ≤ 0.02% span per 10 K scaled by turn down |
| Medium Temperature | Standard: -25 to 125 °C |
| Electronics Temperature | Standard: -25 to 85 °C |
| Storage Temperature | -40 to 100 °C |
| Pressure Port Material | Stainless steel 1.4404 (316L) |
| Housing Material | Stainless steel 1.4404 (316L) |
| Diaphragm Material | Stainless steel 1.4435 (316L) |
| Seals | FKM for PTS 310D versions, others on request |
| Vibration Resistance | 10 g RMS from 20 to 2000 Hz according to DIN EN 60068-2-6 |
| Shock Resistance | 100 g for 11 ms according to DIN EN 60068-2-27 |
| Operational Life | 100 million load cycles |
| CE Conformity | EMC Directive 2014/30/EU |
| Pressure Equipment Directive | 2014/68/EU module A for applicable versions |
| ATEX Conformity | 2014/34/EU for Ex versions |