Features Of The SENSVISION PTS 310F Flush Diaphragm Process Pressure Transmitter
Hygienic Flush Diaphragm Design For Clean Process Measurement
Flush welded stainless steel diaphragm minimizes crevices and supports hygienic installation in food and pharmaceutical systems.High Accuracy Industrial Pressure Measurement Performance
Standard accuracy up to ± 0.35 % span and optional ± 0.25 % span for nominal pressure ranges ≥ 0.4 bar.CIP And SIP Capability For Sanitary Process Integration
Designed for cleaning in place and sterilization in place processes up to 150 °C with suitable sealing materials.Wide Range Of Hygienic Process Connections
Available with flush DIN connections, clamp connections according to DIN 32676, dairy pipe DIN 11851, Varivent, and cone seal options.Configurable Output Signals For Control Systems
Supports 4.20 mA 2 wire and 0 to 10 V or current 3 wire outputs for integration into industrial automation systems.Optional Hazardous Area And Functional Safety Versions
Intrinsically safe Ex ia versions and SIL 2 versions according to IEC 61508 and IEC 61511 available for safety critical processes.Cooling Element Option For High Temperature Media
Optional cooling element supports media temperatures up to 300 °C depending on filling fluid and configuration.
Suitable Applications Of The SENSVISION PTS 310F Hygienic Process Pressure Transmitter
The SENSVISION PTS 310F is engineered for hygienic and safety critical environments where accurate pressure measurement, cleanability, and compliance with industry standards are essential. Its flush diaphragm design and configurable process connections make it ideal for sanitary production lines and regulated facilities.
- Food and beverage production lines
- Pharmaceutical manufacturing processes
- Dairy processing systems
- Brewing and beverage filling systems
- Clean in place and sterilization in place installations
- Bioreactors and fermenters
- Viscous and crystallising media measurement
- Hygienic tanks, vessels, and pipeline monitoring
- Safety related process control with SIL 2 requirements
Technical Specifications Of The SENSVISION PTS 310F Hygienic Flush Pressure Transmitter
| Specification | Detail |
|---|---|
| Product Type | Hygienic industrial pressure transmitter with flush diaphragm |
| Nominal Pressure Range | 0.1 bar to 40 bar |
| Vacuum Range | -1 bar option available with temperature limitation |
| Accuracy Standard | ± 0.35 % span for P ≥ 0.4 bar |
| Accuracy Option | ± 0.25 % span for P ≥ 0.4 bar |
| Accuracy For Low Pressure | ± 0.5 % span for P < 0.4 bar |
| Output Signal 2 Wire | 4.20 mA |
| Output Signal 3 Wire | 0 to 10 V and current variants |
| Supply Voltage | 8 to 32 VDC depending on output and version |
| Long Term Stability | ≤ ± 0.1 % span per year |
| Response Time | < 10 ms 2 wire, ≤ 3 ms 3 wire |
| Medium Temperature Standard | Up to 125 °C depending on filling fluid |
| CIP SIP Capability | Up to 150 °C for 60 minutes at max 50 °C environment |
| Cooling Element Option | Media temperature up to 300 °C depending on configuration |
| Filling Fluids | Silicon oil standard, food grade oil optional |
| Pressure Port Material | Stainless steel 1.4404 316L |
| Diaphragm Material | Stainless steel 1.4435 316L standard, Hastelloy C 276 optional |
| Seals | FKM standard, FFKM optional |
| Surface Roughness Diaphragm | Rₐ < 0.15 µm |
| Surface Roughness Wetted Parts | Rₐ < 0.8 µm |
| Explosion Protection | Ex ia versions available for zone 0 and zone 20 |
| Functional Safety | SIL 2 version according to IEC 61508 and IEC 61511 |
| Operational Life | > 100 million pressure cycles |
| CE Conformity | EMC Directive 2014/30/EU |
| ATEX Conformity | 2014/34/EU for Ex versions |