Titan TPTLRd Low Range Digital Pressure Transmitter, I2C & SPI

The Titan TPTLRd is a low range digital pressure transmitter that pairs a sensitive piezo-resistive silicon sensing element with an onboard microprocessor in a compact stainless steel housing. It reports calibrated pressure readings over I2C or SPI, so it connects straight to a microcontroller, embedded board or data logger with no analog signal conditioning.

Gauge ranges start at just 70 mbar and extend to 20 bar, with accuracy of ≤ ±0.25% or ≤ ±0.10% FS. A 2.7 to 5.5 VDC supply suits 3.3 V and 5 V electronics and battery-powered designs, and M12 or integral cable connections are available with a choice of G1/4, 1/4 NPT and 7/16-20 UNF process ports.

Key Features Of The Titan TPTLRd Low Range Digital Pressure Transmitter

  1. Low Ranges From 70 mbar
    Ten gauge ranges from 70 mbar to 20 bar give fine resolution on low-pressure air, gases and liquids.

  2. Native I2C And SPI Output
    Calibrated digital readings go straight to a microcontroller or host board with no external amplifier or ADC.

  3. Sensitive Silicon Sensing Element
    Silicon piezo-resistive technology with stainless steel wetted parts delivers responsive, repeatable low-pressure measurement.

  4. 2.7 To 5.5 VDC Supply
    Works with both 3.3 V and 5 V logic and is well suited to battery-powered designs.

  5. High Accuracy Options
    Choose ≤ ±0.25% or ≤ ±0.10% FS, with long term stability of ≤ ±0.10% FS.

  6. Compact OEM-Friendly Package
    Stainless steel body with M12 connector or cable outlet and a choice of G1/4, 1/4 NPT and 7/16-20 UNF ports.

Applications For Low Range Digital Pressure Transmitters

The Titan TPTLRd is designed for low-pressure measurement in systems built around digital electronics:

  • Embedded OEM products – low-pressure sensing for blowers, pumps, filtration and dosing equipment with a host microcontroller.
  • Pneumatic testing – monitoring low air pressures in actuators, valves and supply lines.
  • Medical device prototyping – respiratory, flow and fluid-delivery equipment development.
  • Battery-powered data loggers – low supply voltage for long field deployments.
  • Laboratory and research testing – digital readings fed straight into acquisition hardware and test software.
  • Aerospace and automotive research – low-pressure fuel, intake and environmental system test rigs.
  • Academic research and teaching – simple connection to development boards for student and research projects.

How The Titan TPTLRd Digital Pressure Transmitter Works

Low pressures produce very small signals, so the TPTLRd uses a silicon piezo-resistive chip, which is far more sensitive than a thick-film ceramic cell. Pressure on the stainless steel wetted diaphragm is transferred to the silicon bridge, and an onboard microprocessor digitizes the result, applies the factory calibration and temperature compensation, and presents the finished reading on an I2C or SPI bus.

Because the conversion happens inside the sensor, there is no low-level analog signal to amplify, filter or protect from noise. If you need an analog output at these ranges, see the Titan TPTLRa; for higher pressures with a digital output, see the Titan TPTd.

Digital Interfaces And Electrical Connections

  • Digital interfaces – I2C and SPI
  • Supply voltage – 2.7 to 5.5 VDC
  • M12 x 1, 4-pin male connector – IP65 (mating cable available separately)
  • Integral cable outlet – 0.25 m screened PVC cable, IP65
  • Process ports – G1/4 male or female, 1/4 NPT male and 7/16-20 UNF (SAE #4)

Titan TPTLRd Low Range Digital Pressure Transmitter Technical Specifications

SpecificationDetail
Product TypeLow range digital pressure transmitter
Sensor TechnologySilicon piezo-resistive
Digital InterfaceI2C and SPI
Supply Voltage2.7 to 5.5 VDC
Pressure ReferenceGauge (other references on request)
Pressure Ranges70, 200, 350, 700, 1000 mbar; 2, 3.5, 7, 10, 20 bar
Safe Overpressure1.5 x rated range
Burst Pressure3 x rated range
Accuracy≤ ±0.25% or ≤ ±0.10% FS (range dependent)
Long Term Stability≤ ±0.10% FS
Response TimeOptions available on request
Thermal Zero Shift (TZS)±0.02% FS/°C typical
Thermal Span Shift (TSS)< -0.015%/°C typical
Media Temperature-40 to +125 °C
Ambient Temperature-20 to +85 °C
Storage Temperature-20 to +80 °C
Wetted Materials303 and 316 stainless steel, Viton (FKM) seal
Permissible MediaLiquids and gases compatible with the wetted materials
Process ConnectionsG1/4 DIN 3852 male or female, 1/4 NPT male, 7/16-20 UNF-2A male (SAE #4, J514)
Electrical ConnectionsM12 x 1 4-pin male connector; cable outlet with 0.25 m screened PVC cable
Ingress ProtectionIP65
AccessoriesStraight and right-angle M12 cordsets, temperature reducing adaptor

Titan TPTLRd Low Range Digital Pressure Transmitter FAQs

What is the lowest pressure range of the TPTLRd?

The lowest standard range is 70 mbar gauge (about 1 psi), with further ranges at 200, 350, 700 and 1000 mbar and up to 20 bar.

Which digital interfaces does the TPTLRd support?

The TPTLRd supports both I2C and SPI for direct connection to microcontrollers, single board computers and embedded data acquisition systems.

Can the TPTLRd run from a 3.3 V supply?

Yes. It operates from 2.7 to 5.5 VDC, so it works with both 3.3 V and 5 V systems.

What is the difference between the TPTLRd and the TPTd?

Both provide I2C and SPI outputs. The TPTLRd uses a silicon sensor for low ranges from 70 mbar to 20 bar, while the TPTd uses a ceramic sensor for ranges from 0.5 bar to 600 bar.