Features Of The DTISOCON-1-5V-IN-0-20MA-SINK-OUT Analog Signal Converter
Three Port Galvanic Isolation For Signal Protection
Provides full isolation between input, output, and power circuits to eliminate electrical noise, prevent ground loop interference, and ensure stable long term performance.Accurate 1-5V To 0-20mA Current Sink Output Conversion
Converts voltage based signals into a precise 0-20mA sink output suitable for passive current loop applications and industrial input modules.Slim DIN Rail Mountable Industrial Housing
Compact 12.5mm design supports high density installation within control panels, marshalling terminals, and distributed I O enclosures.Wide Range AC Or DC Power Supply Options
Operates from 12 to 36 Vdc or 90 to 264 Vac, enabling flexible deployment across diverse industrial power systems.Independent Zero And Span Calibration Controls
Allows users to adjust device calibration without inputs affecting each other for easier commissioning and maintenance.High Accuracy And Low Temperature Drift
Provides ±0.01 percent typical linearity and minimal thermal variation, ensuring measurement reliability even in demanding environments.Selectable Response Time For Different Process Needs
Offers 25ms fast response or 60ms standard response for smooth and stable output depending on system requirements.Robust Surge And Isolation Protection
Includes heavy duty transient protection and 1 kV continuous isolation to safeguard connected devices and system electronics.
DTISOCON-1-5V-IN-0-20MA-SINK-OUT Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | DTISOCON-1-5V-IN-0-20MA-SINK-OUT |
| Input Signal Type | 1-5V Voltage |
| Input Impedance | 1 MΩ Typical |
| Output Signal Type | 0-20mA Current Sink |
| Output Load Resistance | Up To 750 Ω |
| Output Linearity Error | ±0.01 Percent Typical / ±0.05 Percent Maximum |
| Temperature Coefficient | ±50 ppm Per °C Maximum |
| Load Resistance Error | ±5 ppm Per Ω (0 < R < 750 Ω) |
| Response Time | 25ms Fast Or 60ms Normal |
| Power Supply (DC Version) | 12 To 36 Vdc |
| Power Supply (AC Version) | 90 To 264 Vac |
| Supply Current (24V DC) | 45 mA Typical / 85 mA Maximum |
| Isolation Voltage | 1 kV Continuous |
| Surge Voltage Protection | 2.5 kV For 50µs And 10 kV Per µs Transient |
| Operating Temperature | 0°C To 55°C |
| Relative Humidity | 0 To 90 Percent Non Condensing |
| Mounting Method | DIN Rail TS35 |
| Dimensions | 12.5mm Wide x 114.5mm High x 99mm Deep |
| Terminal Type | Screw Clamp With Pressure Plate |
| Conductor Size Range | 0.5mm² To 4.0mm² |
| Unit Weight | Approximately 95g |
Applications For The DTISOCON-1-5V-IN-0-20MA-SINK-OUT Signal Converter
The DTISOCON-1-5V-IN-0-20MA-SINK-OUT is ideal for situations where voltage based measurement or control signals must be converted into isolated 0-20mA sink outputs for industrial systems. Its robust isolation, high accuracy, and compact DIN rail design make it suitable for both new and retrofit applications across many controlled process environments.
Suitable applications include:
- Converting 1-5V control signals to isolated 0-20mA sink outputs for PLC and DCS systems
- Eliminating ground loop issues in mixed signal automation environments
- SCADA and remote telemetry installations requiring noise immune signal conversion
- Water and wastewater treatment instrumentation requiring isolated current output
- HVAC and building automation systems using 0-20mA feedback loops
- Chemical, petrochemical, and pharmaceutical manufacturing control systems
- Power generation and substation monitoring requiring stable current output signals
- High density industrial panel installations needing compact isolated converters
- Environmental monitoring and air quality measurement systems
- Laboratory, research, and test bench applications using multi range sensors and instruments