Features Of The DTISOCON-4-20MA-IN-0-5V-SOURCE-OUT Analog Signal Converter
Complete Three Port Isolation Architecture
Provides full galvanic isolation between input, output, and power supply to eliminate ground loops and protect against electrical interference and noise.Precision 4-20mA To 0-5V Source Output Conversion
Accurately converts 4-20mA current signals into a stable 0-5V source output for seamless integration with voltage based control systems.Compact DIN Rail Mounting For Control Panels
The slim 12.5mm wide enclosure allows for high density installation on standard TS35 DIN rails to maximize control cabinet space utilization.Flexible AC Or DC Power Supply Options
Supports a wide range of power inputs including 12 to 36 Vdc or 90 to 264 Vac to accommodate various industrial power configurations.Integrated Isolated Transmitter Power Supply
Features a built in isolated supply capable of powering standard 2 wire 4-20mA field transmitters and devices directly from the converter.Non Interactive Zero And Span Adjustment Controls
Equipped with independent calibration controls that allow for quick and precise adjustment without interaction between the zero and span settings.High Accuracy And Low Temperature Drift Performance
Delivers typical linearity error of ±0.01 percent with low temperature coefficient of ±50ppm per °C for consistent signal integrity.Selectable Response Time For Process Optimization
Offers user selectable fast or normal response times of 25ms or 60ms to match the specific dynamics of the application.
DTISOCON-4-20MA-IN-0-5V-SOURCE-OUT Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | DTISOCON-4-20MA-IN-0-5V-SOURCE-OUT |
| Input Signal Type | 4-20mA Current |
| Input Impedance | 15 Ω Typical |
| Voltage Drop At Input | 0.3 V At 20mA |
| Output Signal Type | 0-5V Voltage Source |
| Output Load Impedance | Minimum 100 kΩ |
| Output Linearity Error | ±0.01 Percent Typical / ±0.05 Percent Maximum |
| Temperature Coefficient | ±50 ppm Per °C Maximum |
| Load Resistance Error | ±5 ppm Per Ω (0 < R < 750 Ω) |
| Response Time (10-90 Percent) | 25ms (Fast) / 60ms (Normal) Selectable |
| Power Supply (DC Version) | 12 To 36 Vdc |
| Power Supply (AC Version) | 90 To 264 Vac |
| Supply Current (24V DC) | 45 mA Typical / 85 mA Maximum |
| Isolation Voltage | 1 kV Continuous |
| Surge Voltage Protection | 2.5 kV For 50µs / 10 kV Per µs Transient |
| Operating Temperature | 0°C To 55°C |
| Relative Humidity | 0 Percent To 90 Percent Non Condensing |
| Mounting Type | DIN Rail TS35 |
| Enclosure Dimensions | 12.5mm Wide x 114.5mm High x 99mm Deep |
| Connection Type | Screw Clamp With Pressure Plate |
| Conductor Size Range | 0.5mm² To 4.0mm² |
| Weight | Approximately 95g |
Applications For The DTISOCON-4-20MA-IN-0-5V-SOURCE-OUT Signal Converter
The DTISOCON-4-20MA-IN-0-5V-SOURCE-OUT is designed for applications where 4-20mA current signals must be converted to isolated 0-5V voltage signals for control system operation and monitoring. By providing 3 port isolation and high accuracy current to voltage conversion, the unit protects control equipment from ground potential differences, electrical noise, and wiring issues common in industrial environments. Its compact DIN rail format, wide power supply range, and integrated transmitter power make it well suited to both new installations and retrofit projects across many industrial sectors.
Suitable applications include:
- Interfacing 4-20mA field signals with PLC and DCS 0-5V analog inputs
- Ground loop elimination in signal circuits between field devices and control systems
- Signal conditioning for SCADA systems requiring current to voltage conversion
- Isolation of measurement signals in water and wastewater treatment automation
- Current to voltage interface for building management and HVAC control systems
- Protection of control instrumentation in power generation and distribution facilities
- Signal conversion in chemical and pharmaceutical manufacturing control systems
- High density signal marshalling in oil and gas production control rooms
- Environmental monitoring systems requiring isolated current to voltage interfacing
- Industrial machinery and automation control requiring compact isolated converters
- Test and measurement setups where current outputs must drive voltage based instruments
- Remote telemetry and data acquisition station signal conditioning